Monday, January 26, 2009

Spaghetti Production

From the second batch of the Project MH, spaghetti of 1.5 and 0.5 was produced from ES 26g and 52g.

Production of 1.5 mm did not have any problem while 0.5 production (extrusion) had a problem. Time to time the extrusion was stopped because of some granules stuck inside or above the 0.5 die. So it had to be cleaned each and every time it stops making the process longer.

For Al2O3 project another 4 number of samples (fibers) were prepared and put to the furnace using another program which was changed according to the TGA results.

Monday, January 19, 2009

Fiber Project

After doing the sintering process with the fiber specimens, it is realized that there is something wrong either in the firing program or in the material. So a TG (thermogravimetric) analysis had to be done.

I have received the results from the TG analysis and drew the graph according that. There I could obviously see that the firing curve I used was wrong. Because the decomposition of the inner core of the fiber overlaps with the debinding process of the outer layer (The layer which should be remained after sintering).

So I changed the firing curve very carefully considering some factors according to the TG analysis results. I will sinter some more samples very sooner to check the effects.

Saturday, January 17, 2009

Getting Better

The fingers which were squeezed in last year just before the Christmas days are now getting better. It seems that I am going to loose the two nails and at the same time coming new nails. Have to be so careful when working, not to stick with anything around. Otherwise the nails will be forcefully removed making a great disaster. ;)

I am really wondering how nicely the human body works. It is wonderful and amazing.

-- cheers

Friday, January 16, 2009

Rechecking Calibration

Calibration of the Sensors had been done by the service maintenance and I wanted to recheck the data I gathered earlier with the Micra-M device.

Problem: There were some transducers like 1400 bar transducer for what the Micra-M can't be calibrated because of the limitation of the calibration device we had. It can only go upto 550 bars since it is calibrated only till that pressure. but it can go upto 1000 bars. So tried to calibrate it until 1000 bars. But the values were getting a difference when the values are out of the range 200 - 500 bar. For the 350 bar sensor it was hard to calibrate Micra-M because it showed different input values each and every time it is rechecked.

Compression test of some ceramic rods were done according to a German norm. It is obvious that the sample preparation according to the norm is not that easy and it has an effect on the strength test.
The test was done on four types of batches and it is seen that one is really good in strength and the strength has been almost doubled than the last batch.

For another project, some tubes had to be sintered and one was put to the kiln to be debindered with the given temperature curve. To be certain about the results only one type of tubes was used rather than all the types. So one can be sure on the results when interpret them.

So at last it is another week end.. :)

Thursday, January 15, 2009

Happy and Feel great.

I finished writing the Micra-M and DaqPRO programming manual which consists of 13 pages including front and contents page and the Data sheet pages too. Started today with writing the programming of DaqPRO and had to take some pictures of the device since the pictures I had were not enough giving details.
After all finished the manual gave handed it over to the supervisor. His appreciation is motivating. It is really nice to have that kind of appreciation after doing some work.
Thanks Frank. You are really a good and a kind supervisor.

(Asked Frank for the permission to participate to the BrainStore workshop and he granted the permission. Such a nice person.)

Wednesday, January 14, 2009

Writing Manual

I am continuing my writing of the manual putting all the data available in a correct order. I have to write about two devices. One is the Micra-M Digital Instrument and the DaqPRO Data Logger. DaqPRO Data Logger is used to acquire the output from the Micra-M on a computer and save data for later use. It can be programmed to use with different sensors and save the defined sensors.
Have to insert some guiding pictures to assist the user to make more sense about the process. At the end of the day I totally finished writing about the Micra-M programming and tomorrow have to start with DaqPRO programming.

-- cheers

Tuesday, January 13, 2009

Micra-M manual

Now I am fully equipped with the details of the Micra-M device. So started writing the manual of which the main requirement is to give the user a proper idea how to create it. Brief introduction and overview to the programming method was written. But have to finish all the parts before tomorrow afternoon. Have to get some more data for another transducer too. for 350 bar transducer.